Partial inerting - A possible means of eliminating the brush-discharge-ignition hazard with explosive gases and vapours?

机译:部分惰化-一种消除爆炸性气体和蒸气的电刷放电点燃危险的可能方法?

获取原文
获取原文并翻译 | 示例
           

摘要

It was found that the brush discharge ignition hazard with IIA gases/vapours (propane) can be eliminated by reducing the oxygenitrogen volume ratio in the atmosphere to the order of 15/85. The condition is that the diameter of the earthed electrode ≤ 40 mm. Published information on whether an oxygenitrogen ratio of 15/85 is acceptable as regards the oxygen deficiency hazards is contradictory. With IIB gases/vapours (ethylene) the oxygenitrogen ratio must be reduced to at least 10/90 to eliminate the brush-discharge-ignition hazard. Lowering the oxygenitrogen ratio to this level will undoubtedly present a substantial oxygen deficiency hazard to humans.
机译:已发现,通过将大气中的氧气/氮气体积比降低到15/85左右,可以消除IIA气体/蒸气(丙烷)引起的电刷放电着火危险。条件是接地电极的直径≤40 mm。关于氧缺乏危害,氧/氮比为15/85是否可以接受的公开信息是矛盾的。对于IIB气体/蒸气(乙烯),必须将氧气/氮气比降低到至少10/90,以消除电刷放电点燃的危险。将氧/氮比降低到该水平无疑将对人体造成严重的缺氧危害。