We evaluate the uncertainty associated with the critical current measurement of high-temperature superconducting power cables in which a power-law fit of a voltage-current characteristic is used to determine the critical current. We calculate the uncertainty contribution of each factors involved in the critical current measurement and find that the largest contribution to the combined standard uncertainty comes from the process of the power-law fit. This analysis can be applied to the uncertainty evaluation on the critical current measurement of superconducting wires.
机译:我们评估与高温超导电力电缆的临界电流测量相关的不确定性,其中使用电压-电流特性的幂律拟合确定临界电流。我们计算了关键电流测量中涉及的每个因素的不确定性贡献,发现对组合标准不确定性的最大贡献来自幂律拟合过程。该分析可用于超导线的临界电流测量的不确定性评估。