首页> 外文期刊>CompressorTech Two: Dedicated to Gas Compression Products and Applications >Impact Of Reciprocating Compressor Pulsations On The Surge Margin Of Centrifugal Compressors (Part 2) Testing facilities and surge line verification
【24h】

Impact Of Reciprocating Compressor Pulsations On The Surge Margin Of Centrifugal Compressors (Part 2) Testing facilities and surge line verification

机译:往复式压缩机脉动对离心式压缩机喘振裕度的影响(第2部分)测试设备和喘振线验证

获取原文
获取原文并翻译 | 示例
           

摘要

To determine the impact of externally induced pulsations on the surge margin of the centrifugal compressor, the reciprocating compressor is operated upstream in series with the centrifugal compressor. The pulsations from the reciprocating compressor travel through 55 ft. (16.76 m) of varying diameter pipe, as shown on the P&ID, before they enter the centrifugal compressor suction flange. Some pulsation attenuation or acoustic amplification will occur in this pipe segment and must be quantified for the analysis. Time domain pulsations were measured at the reciprocating compressor discharge, the centrifugal compressor suction, and the centrifugal compressor discharge.
机译:为了确定外部引起的脉动对离心压缩机的喘振裕度的影响,往复式压缩机在上游与离心压缩机串联操作。往复式压缩机产生的脉冲在进入离心式压缩机吸入法兰之前,先经过55英尺(16.76 m)的变径管,如P&ID所示。在此管段中会发生一些脉动衰减或声音放大,必须对其进行量化以进行分析。在往复式压缩机排气口,离心式压缩机吸气口和离心式压缩机排气口处测量时域脉动。