摘要

The constant-rate discharge control system is used for dams to keep their water levels constant and is operated under automatic control. However, the performance record of the system shows some problems: (1 the control fluctuation margin is not small, and (2) spillway gates are operated too frequently. In addition, the automatic constant-rate discharge control system is often manually operated in flood situation. As the existing constant-rate discharge control system is operated based on an inlet rate, it is necessary to gauge the water level fluctuation accurately to calculate the dam water volume. However, the water level is affected by various disturbances. In fact, it is impossible to detect accurate water levels in case of short-time fluctuations such as waves or in case of medium- and long-time fluctuations such as seiche phenomenon due to increase or decrease of inlet and discharge water. Thus, the calculation of a dam water volume is inaccurate, and the inlet rate to determine the control volume cannot also be determined accurately, resulting in problems such as control delay, bunching and overshooting. To solve to these technical problems, a new automatic flood gate control system has been developed, in which the target inlet value is calculated by ARX (Auto-Regressive with External input) method.
机译:恒流量控制系统用于大坝,以保持其水位恒定,并在自动控制下运行。但是,该系统的性能记录存在一些问题:(1控制波动余量不小,(2)溢洪道闸门操作过于频繁;此外,自动恒流排放控制系统经常在洪灾中手动操作。由于现有的恒定流量控制系统是基于进水速度运行的,因此有必要准确地测量水位波动以计算大坝水量,但是水位会受到各种干扰的影响。由于进水和出水的增加或减少,在短时波动(例如波浪)或中长期波动(例如seiche现象)的情况下,无法检测到准确的水位。大坝水量不准确,确定控制量的进水率也无法准确确定,导致控制延迟,聚束,超调等问题。针对这些技术问题,开发了一种新的自动水闸控制系统,其中目标入口值通过ARX(外部输入自动回归)方法进行计算。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号