In this paper a novel construction of an active quenching circuit intended for single-photon detection is presented, along with a few original methods for its evaluation. The circuit has been combined with a standard avalanche photodiode C30902S to form a single-photon detector. This detector has a dead time of 39 ns, maximum random counting frequency of 14 MHz, small afterpulsing probability, an estimated peak detection efficiency of over 20percent, and a dark count rate of less than 100 Hz. This simple and robust active quenching circuit can be built from off-the-shelf electronic components and is presented with the detailed schematic diagram.
机译:在本文中,提出了一种用于单光子检测的有源猝灭电路的新颖结构,以及一些对其进行评估的原始方法。该电路已与标准雪崩光电二极管C30902S结合在一起,形成了一个单光子检测器。该检测器的空载时间为39 ns,最大随机计数频率为14 MHz,后脉冲概率小,估计的峰值检测效率超过20%,暗计数率小于100 Hz。这种简单而强大的有源淬火电路可以由现成的电子组件构建而成,并带有详细的原理图。