We propose an integrating sphere photometer with six detection ports for total luminous flux measurement, which significantly improves the uniformity of spatial response compared to the conventional single-port detection design. Numerical simulations based on the geometric radiative transfer equation show that a spatial response distribution function of the new design is uniform within 2percent with respect to all spatial directions. The related spatial mismatch error is calculated to be less than 0.3percent for all the realistic cases of angular intensity distribution of a test lamp. As a result, the new design practically eliminates the spatial mismatch error of an integrating sphere photometer, so that a high-accuracy measurement can be achieved without the complicated spatial mismatch correction procedure.
机译:我们提出了一种带有六个检测端口的积分球光度计,用于总光通量测量,与传统的单端口检测设计相比,它可以显着提高空间响应的均匀性。基于几何辐射传递方程的数值模拟表明,新设计的空间响应分布函数相对于所有空间方向均在2%以内。对于测试灯的角强度分布的所有实际情况,计算出的相关空间失配误差均小于0.3%。结果,新设计实际上消除了积分球光度计的空间失配误差,从而无需复杂的空间失配校正程序就可以实现高精度的测量。