In this Letter, a hybrid interferometer for simultaneous measurement of the partial pressures of O_(2) and CO_(2) mixtures is reported. The sensing head consists in the combination of two interferometric structures, one a Fabry-Perrot cavity and the other a modal interferometer. The intrinsic Fabry-Perot was formed by splicing a single mode fiber with a graded index fiber length that was then subjected to chemical etching creating an air cavity. The second interferometer is based on a splice of a pure silica tube in series with the Fabry-Perot. It was observed for a particular gas that its refractive index changes with pressure variation in a specific way, a characteristic that permitted the simultaneous measurement of partial pressures of CO_(2) and O_(2) with rms deviations of approx +-48.7 kPa and approx +- 20.1 kPa, respectively.
机译:在这封信中,报告了一种混合干涉仪,用于同时测量O_(2)和CO_(2)混合物的分压。传感头由两种干涉结构组成,一种是法布里-珀罗腔,另一种是模态干涉仪。固有的Fabry-Perot是通过将具有渐变折射率光纤长度的单模光纤拼接起来,然后对其进行化学蚀刻而形成的。第二个干涉仪基于与Fabry-Perot串联的纯硅胶管的接头。对于一种特定的气体,观察到其折射率随压力的变化以特定的方式变化,该特性允许同时测量rms偏差约为+ -48.7 kPa和rms偏差的CO_(2)和O_(2)的分压。分别约为±20.1kPa。