An ultrafast flow modulation period, P-M of 50 ms, for comprehensive two-dimensional (2D) gas chromatography (GC x GC) with time-of-flight mass spectrometry (TOFMS) detection is demonstrated, producing narrow peak widths, W-2(4 sigma width-at-base on the D-2 dimension), demonstrating the potential for ultrafast (2D) separations with high peak capacity. The modulator is a pulse flow valve that injects a narrow pulse of carrier gas at a user defined P-M, at the union between the D-1 and D-2 columns. The raw data produced combines the properties of vacancy chromatography and frontal analysis. Deconvolution of the raw data using unconstrained multivariate curve resolution alternating least squares (MCR-ALS) analysis facilitates identification and quantification for overlapped analyte peaks. The peak profile loadings obtained from MCR-ALS are converted into traditional appearing GC x GC data through a process commonly used with frontal analysis. An 18-component test mixture at seven different injected mass levels was studied. The D-2 peaks generated ranged from an W-2 of 16 to 36 ms with an average of 26 ms. At an on-column injected mass of 14 ng per analyte, an average mass spectral match value, MV, of 822 was achieved using in-house collected spectra for comparison, with an average match value RSD of 7.1%. Calibration of overlapped test analytes was evaluated using the areas of the MCR-ALS loadings, with excellent quantification demonstrated. The advancement demonstrated in modulation performance for GC x GC represents a significant decrease in P-M as most commercial modulators have a minimum P-M of 1 s, while maintaining the benefits of a duty cycle of essentially 1.0, which promises to enable new chemical analyzer designs, compatible with the vacuum requirements of the TOFMS detector. (C) 2018 Elsevier B.V. All rights reserved.
机译:对综合二维(2D)气相色谱(GC X GC)具有飞行时间质谱(TOFMS)检测的超快流量调制周期,PM为50ms,产生窄峰宽度,W-2( D-2尺寸的4个Sigma宽度底座),展示超快(2D)具有高峰容量的电位。调制器是脉冲流量阀,其在D-1和D-2列之间的UNION处在用户定义的P-M处注入载气的窄脉冲。产生的原始数据结合了空位色谱和额度分析的性质。使用无约束多变量曲线分辨率交替最小二乘(MCR-ALS)分析的原始数据的去卷积有助于识别和定量重叠的分析物峰。通过常规分析通常使用的方法将从MCR-ALS获得的峰值轮廓加载到传统的GC X GC数据中。研究了七种不同注入质量水平的18组分试验混合物。产生的D-2峰值范围为16至36ms的W-2,平均为26ms。在每分析物的14ng的柱状物质中,使用内部收集的光谱实现了822的平均质谱匹配值MV,以进行比较,平均匹配值RSD为7.1%。使用MCR-ALS载荷的区域评估重叠测试分析物的校准,并证明了优异的量化。在GC X GC的调制性能下表现出的进步表示PM的显着降低,因为大多数商业调制器具有最小PM的PM为1 S,同时保持基本上1.0的占空比的好处,这承诺使新的化学分析仪设计能够设计,兼容具有TOFMS检测器的真空要求。 (c)2018年elestvier b.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号