首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Analysis of brominated and chlorinated flame retardants, organophosphate esters, and polycyclic aromatic hydrocarbons in silicone wristbands used as personal passive samplers
【24h】

Analysis of brominated and chlorinated flame retardants, organophosphate esters, and polycyclic aromatic hydrocarbons in silicone wristbands used as personal passive samplers

机译:用作个人被动采样器的硅胶腕带中溴化和氯化阻燃剂,有机磷酸酯和多环芳烃的分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

For the first time, we present an analytical method to simultaneously extract, fractionate, and quantify four groups of semi-volatile organic compounds (SVOCs) in silicone wristbands, including 35 polybrominated diphenyl ethers (PBDEs), 10 novel flame retardants (NFRs), 19 organophosphate esters (OPEs), and 13 polycyclic aromatic hydrocarbons (PAHs). Wristbands were extracted using ultrasonication, and cleaned and fractionated on two multi-layer columns: one consisting of neutral alumina, neutral silica and Florisil, and the other consisting of neutral alumina, neutral silica, and acidic silica. Method accuracy and precision were validated using spiked wristband samples (n = 8) and procedural blanks (n = 7). Average matrix spike percent recoveries for all target analytes were within 57-107% with relative standard errors < 20%, with a few exceptions. This method was applied to analyze thirteen wristbands worn by ten participants for seven days; three participants wore two wristbands to evaluate duplicate samples. Percent recoveries of surrogate standards for all four groups of analytes in these wristbands were all within the 80-120% range with a few exceptions: recoveries for C-13(12) BDE-209 and for C-13(12)-triphenyl phosphate ranged from 35 to 62% and 69-176%, respectively. The majority of target analytes were detected in at least half of worn wristbands. The levels of total PBDEs, NFRs, OPEs and PAHs in deployed wristbands ranged from 28.4 to 412 ng, 40.7 to 625 ng, 2440 to 9580 ng, and 76.2 to 1240 ng, respectively. (C) 2018 Elsevier B.V. All rights reserved.
机译:我们首次出示一种分析方法,同时提取,分馏和量化硅氧烷腕带中的四组半挥发性有机化合物(SVOC),包括35种多溴二苯醚(PBDE),10个新的阻燃剂(NFR), 19个有机磷酸酯(Opes)和13个多环芳烃(PAH)。使用超声波提取腕带,并在两个多层柱上清洗和分馏:由中性氧化铝,中性二氧化硅和Florisil组成的,另一组由中性氧化铝,中性二氧化硅和酸性二氧化硅组成。使用尖刺腕带样品(n = 8)和程序坯料(n = 7)验证了方法精度和精度。所有靶分析物的平均基质百分比回收率在57-107%以内,相对标准误差<20%,具有几种例外。该方法用于分析十名参与者七天穿的十三个腕带;三位参与者穿着两个腕带来评估重复的样本。这些腕带中所有四组分析物的替代标准的百分比百分比均为80-120%的范围内,少数例外:C-13(12)BDE-209的回收率和C-13(12) - 磷酸苯基范围分别为35至62%和69-176%。大多数靶分析物在至少一半的磨损腕带中检测到。部署腕带的总PBDE,NFR,OPE和PAHs的水平范围为28.4至412 ng,40.7至625 ng,分别为9580 ng,76.2至1240 ng。 (c)2018年elestvier b.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号