Rationale and Objectives: To optimize visualization of lenticulostriate artery (LSA) by time-of-flight (TOF) magnetic resonance angiography (MRA) with slice-selective off-resonance sinc (SORS) saturation transfer contrast pulses and to compare capability of optimal TOF-MRA and flow-sensitive black-blood (FSBB) MRA to visualize the LSA at 3T. Materials and Methods: This study was approved by the local ethics committee, and written informed consent was obtained from all the subjects. TOF-MRA was optimized in 20 subjects by comparing SORS pulses of different flip angles: 0, 400°, and 750°. Numbers of LSAs were counted. The optimal TOF-MRA was compared to FSBB-MRA in 21 subjects. Images were evaluated by the numbers and length of visualized LSAs. Results: LSAs were significantly more visualized in TOF-MRA with SORS pulses of 400° than others (P < .003). When the optimal TOF-MRA was compared to FSBB-MRA, the visualization of LSA using FSBB (mean branch numbers 11.1, 95% confidence interval (CI) 10.0-12.1; mean total length 236 mm, 95% CI 210-263 mm) was significantly better than using TOF (4.7, 95% CI 4.1-5.3; 78 mm, 95% CI 67-89 mm) for both numbers and length of the LSA (P < .0001). Conclusions: LSA visualization was best with 400° SORS pulses for TOF-MRA but FSBB-MRA was better than TOF-MRA, which indicates its clinical potential to investigate the LSA on a 3T magnetic resonance imaging.
机译:原理和目的:通过飞行时间(TOF)磁共振血管造影(MRA)和切片选择非共振Sinc(SORS)饱和转移造影剂脉冲来优化小腿动脉(LSA)的可视化,并比较最佳TOF的能力-MRA和流量敏感的黑血(FSBB)MRA,以在3T时可视化LSA。资料和方法:本研究得到当地伦理委员会的批准,并从所有受试者中获得书面知情同意。通过比较不同翻转角(0、400°和750°)的SORS脉冲,优化了20位受试者的TOF-MRA。计算了LSA的数量。在21位受试者中,将最佳TOF-MRA与FSBB-MRA进行了比较。通过可视化LSA的数量和长度评估图像。结果:在400°SORS脉冲下,TOF-MRA中的LSA显着高于其他(P <.003)。将最佳TOF-MRA与FSBB-MRA进行比较时,使用FSBB可视化LSA(平均分支数11.1,95%置信区间(CI)10.0-12.1;平均总长度236 mm,95%CI 210-263 mm) LSA的数量和长度均明显优于使用TOF(4.7,95%CI 4.1-5.3; 78 mm,95%CI 67-89 mm)(P <.0001)。结论:对于TOF-MRA,LSA可视化效果最好为400°SORS脉冲,但FSBB-MRA优于TOF-MRA,这表明其在3T磁共振成像上研究LSA的临床潜力。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号