Objectives The aim of this study was to investigate of salivary gland dysfunction with single-photon emission computed tomography/computed tomography (SPECT/CT), especially the relationship between maximum standardized uptake value (SUVmax) of salivary glands and their dysfunction. Methods Five patients (2 submandibular sialolithiasis, 2 Sjogren's syndrome, and 1 parotitis) who underwent SPECT/CT were included in this study. The salivary gland excretion function was defined as A (pre-stimulatory 20 min after injection of Tc-99m pertechnetate)/B (post-stimulatory 40 min after injection of Tc-99m pertechnetate) using SUVmax of parotid and submandibular glands. Results SUVmax before stimulation of the submandibular gland with sialoliths in a patient was lower than that in the opposite submandibular gland without sialoliths (5.81 vs 51.37). Furthermore, the A/B using SUVmax in the other patient of submandibular glands with sialoliths was lower than that in the opposite submandibular glands without sialoliths (0.70 vs 1.85). The A/B using SUVmax of right and left parotid gland in a patient with Sjogren's syndrome was 1.06 and 0.74, respectively. Furthermore, the A/B using SUVmax of right and left parotid glands in the other patient with Sjogren's syndrome was 3.20 and 4.32, respectively. The A/B using SUVmax of right and left parotid glands in a patient with left parotitis was 2.26 and 1.58, respectively. Conclusion The results of the present study indicate that SUVmax using SPECT/CT seems a useful tool for evaluation of the salivary gland dysfunction.
机译:本研究的目的是利用单光子发射计算断层扫描/计算断层扫描(SPECT / CT)来研究唾液腺功能障碍,尤其是唾液腺的最大标准化摄取值(SUVMAX)与其功能障碍之间的关系。方法本研究纳入了五名患者(2次颌下性Sialolithiais,2次Sjogren综合征和1个耳炎)。唾液腺排泄功能定义为(注射TC-99M钙酸酯后20分钟的预刺激20分钟)使用腮腺和颌下腺的SUVMAX注射刺激后40分钟后刺激40分钟。结果刺激患者中羊毛腺体前的Suvmax低于患者的患者的潜水腺(5.81 Vs 51.37)的相对潜水腺中的潜水腺体。此外,使用Sialliths的其他患者使用Suvmax的A / B低于没有西亚利斯(0.70 Vs 1.85)的相对潜水腺的患者。使用Sjogren综合征的患者的右侧和左侧腮腺的SUVMAX的A / B分别为1.06和0.74。此外,使用Sjogren综合征的其他患者的使用右侧和左侧腮腺的A / B分别为3.20和4.32。使用左侧耳炎的患者的右侧和左侧腮腺的SUVMAX的A / B分别为2.26和1.58。结论本研究的结果表明,使用SPECT / CT的SUVMAX似乎是评估唾液腺功能障碍的有用工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号