首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Biomechanical Evaluation of a Transtendinous All-Suture Anchor Technique Versus Interference Screw Technique for Suprapectoral Biceps Tenodesis in a Cadaveric Model
【24h】

Biomechanical Evaluation of a Transtendinous All-Suture Anchor Technique Versus Interference Screw Technique for Suprapectoral Biceps Tenodesis in a Cadaveric Model

机译:一种尸体锚固锚技术对尸体二头肌尸体锚杆技术对尸体模型的干扰螺杆技术的生物力学评价

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To compare the biomechanical properties of an transtendinous all-suture anchor technique with the commonly-accepted interference screw technique in a cadaveric model. Methods: Sixteen fresh-frozen human cadaveric shoulders (mean age, 67.6 +/- 5.8 years) were used and were randomly divided into 2 experimental long head of the biceps brachii (LHB) tenodesis groups (n = 8), namely transtendinous all-suture anchor technique and interference screw technique. The location of tenodesis was in the bicipital groove, 1 cm distal to the proximal border of the bicipital groove. Tensile force parallel to the longitudinal axis of the humerus was applied to each specimen. A preload of 5 N was applied for 2 minutes, followed by cyclic loading for 500 cycles from 5 to 70 N at 1 Hz; then, a load-to-failure test at 1 mm/s was performed. The ultimate failure load, stiffness, cyclic displacement, failure displacement, and failure modes were recorded. Results: The transtendinous all-suture anchor technique provided similar ultimate failure load and stiffness as the interference screw technique. However, the cyclic and failure displacements of the transtendinous all-suture anchor technique were significantly greater than the interference screw technique (P = .009 and .021, respectively). Six specimens in the transtendinous all-suture anchor group failed because of suture anchor pullout, while failure of the other 2 was caused by tendon tear; by contrast, all specimens in the interference screw group failed because of tendon tear. Conclusions: The transtendinous all-suture anchor technique for LHB tenodesis offered equivalent ultimate failure load and stiffness but had significantly larger cyclic and failure displacement values when compared with the interference screw technique in this cadaveric biomechanical study.
机译:目的:比较在尸体模型中与常用的干涉螺杆技术进行垂直的全缝合锚固技术的生物力学特性。方法:使用16个新鲜冷冻的人尸体肩部(平均年龄,67.6 +/- 5.8岁),随机分为二头肌(LHB)冠状动物组(n = 8)的2个实验长头,即扭曲的全部 - 缝合锚技术和干涉螺杆技术。成品的位置位于双皮槽,远端的1厘米,近侧凹槽的近侧边缘。将与肱骨的纵向轴线平行的拉伸力施加到每个样本上。将5 n的预载荷施加2分钟,然后将500次循环从5至70n循环为1 Hz;然后,进行1mm / s的负载失效测试。记录了最终的故障负载,刚度,循环位移,故障位移和故障模式。结果:垂直的全缝合锚技术提供了类似的最终故障负载和刚度作为干涉螺杆技术。然而,垂直的全缝合线锚固技术的循环和失效位移显着大于干扰螺杆技术(分别为P = .009和.021)。展台全缝合线锚组的六个标本由于缝合锚闸门而失败,而另一个2的失败是由肌腱撕裂引起的;相比之下,由于肌腱撕裂,干扰螺钉组中的所有标本都失败。结论:LHB成本的Transtencinous全缝合锚技术提供了相当于最终的失效负载和刚度,但与该尸体生物力学研究中的干扰螺杆技术相比,循环和失效位移值显着更大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号