Comparison of conventional ultrasound and real-time spatial compound imaging in evaluation of patients with severe Peyronie's disease.

机译:常规超声和实时空间复合成像在严重Peyronie病患者评估中的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Real-time spatial compound imaging (C-US) is an ultrasound (US) method which effectively reduces image artifacts and noise. In contrast to conventional techniques, multiple frames are acquired from different viewing angles and combined to form a single compound image. PURPOSE: To evaluate whether C-US improves ultrasound evaluation of patients with severe Peyronie's disease. MATERIAL AND METHODS: 60 consecutive patients with severe Peyronie's disease underwent conventional US and C-US after intracavernous prostaglandin E1 injection. Corresponding images of the same scan plane were obtained with both methods, and subjective image quality was scored retrospectively using a four-point scale by two blinded readers with different experience in penile imaging. Readers focused on evaluation of the tunica albuginea, plaques, involvement of the penile septum, and overall image quality. Also, presence of large albugineal calcifications or microcalcifications was considered. To assess intrareader agreement, both readers repeated evaluation after a 1-month interval. Statistical analysis was performed using the Wilcoxon signed-rank test and McNemar test. Weighted kappa values were calculated to assess intra- and inter-reader agreement. RESULTS: Average scores were significantly higher for reader 1 (P0.001). Both readers rated C-US better (P0.001) than conventional US. Despite higher image quality scores, C-US was as effective as conventional grayscale US in assessing involvement of the penile septum. No differences were found between the two methods for visualization of large calcifications, while microcalcifications were better visible with compound imaging. Intrareader agreement was higher for the more experienced reader 1. CONCLUSION: C-US is subjectively superior to conventional US in evaluating patients with severe Peyronie's disease.
机译:背景技术:实时空间复合成像(C-US)是一种超声(US)方法,可有效减少图像伪影和噪声。与常规技术相反,从不同的视角获取多个帧并将其合并以形成单个复合图像。目的:评估C-US是否能改善严重佩隆尼氏病患者的超声评估。材料与方法:连续60例严重的Peyronie's病患,在腔内注射前列腺素E1后接受常规US和C-US检查。两种方法均获得了相同扫描平面的相应图像,并且由两名在阴茎成像方面经验不同的盲人读者使用四点量表对主观图像质量进行了回顾性评分。读者侧重于白膜,斑块,阴茎隔的累及整体图像质量的评估。另外,考虑到存在较大的白膜钙化或微钙化。为了评估读者之间的一致性,两个读者在间隔1个月后重复评估。使用Wilcoxon符号秩检验和McNemar检验进行统计分析。计算加权κ值以评估读者之间和读者之间的一致性。结果:阅读器1的平均得分明显更高(P <0.001)。两位读者对C-US的评价都优于常规US(P <0.001)。尽管图像质量得分较高,但C-US在评估阴茎隔膜的受累方面与常规灰度US一样有效。两种显示大钙化的方法之间没有发现差异,而通过复合成像可以更好地看到微钙化。对于经验丰富的阅读者,阅读器内部的一致性更高。1.结论:在评估严重佩罗尼氏病的患者时,C-US在主观上优于常规US。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号