OBJECTIVE: To determine the incidence of fluid reflux from the lower urinary tract into the connecting tubing used for irrigation in patients undergoing flexible cystoscopy. PATIENTS AND METHODS: The study was conducted in 94 consecutive male and female patients attending routine outpatient flexible cystoscopy lists. A sensor was designed and constructed to determine the presence of any retrograde flow of irrigating fluid, and the volume of any reflux through the connecting tubing. The mean (sd) cystoscope internal channel volume was 2.56 (0.25) mL; the level of significant reflux was set at >/=2. 25 mL. RESULTS: Reflux of irrigating fluid occurred in 11 males (17%) and was significant in six (9%) of 65 male patients, with the irrigating fluid reservoir set at a height of 0.78 m above the patient's mid-coronal level. No reflux occurred in the 29 females studied. CONCLUSIONS: Significant reflux can occur in males and hence the connecting tubing should be regarded as contaminated. Infection-control measures must include the prevention of transmission of blood-borne infections, e.g. hepatitis B and C viruses, and human immunodeficiency virus, because of the risk that blood may contaminate urine, and they should be implemented in all cases regardless of patient risk factors. From the available evidence, flexible cystoscopy should always be performed with single-use irrigation systems.
机译:目的:确定进行柔性膀胱镜检查的患者从下尿路到用于冲洗的连接管中的液体回流的发生率。患者与方法:该研究是在94名连续参加常规门诊柔性膀胱镜检查的男性和女性患者中进行的。设计并构造了一个传感器,用于确定冲洗液是否有任何逆流,以及通过连接管的任何回流量。膀胱镜内部通道的平均(sd)为2.56(0.25)mL;显着回流的水平设置为> / = 2。 25毫升结果:65名男性患者中有11名男性(17%)发生了冲洗液反流,在6名(9%)中有显着性,冲洗液储罐的高度设在患者冠状动脉中位以上0.78 m。在所研究的29位女性中未发生反流。结论:雄性可能发生大量反流,因此应将连接管视为已污染。感染控制措施必须包括防止血源性传染病的传播,例如由于血液可能污染尿液,因此存在乙型和丙型肝炎病毒以及人类免疫缺陷病毒,因此无论患者的危险因素如何,均应在所有情况下实施。从现有证据来看,灵活的膀胱镜检查应始终使用一次性冲洗系统进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号