首页> 外文期刊>Trends in Ecology & Evolution >Technical Evaluation and Optimization of Phasor Measurement Unit Using CSIR-NPL PMU Calibrator System to Ensure Reliability
【24h】

Technical Evaluation and Optimization of Phasor Measurement Unit Using CSIR-NPL PMU Calibrator System to Ensure Reliability

机译:使用CSIR-NPL PMU校准系统的Phasor测量单元的技术评估和优化,以确保可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

The technological enhancements and new startups in India have led to a tremendous increase in the power demand. The grids are being made smart, more efficient and reliable to meet not only the growing energy demands but also to prevent blackouts. The synchrophasor technology is evolving, explored and used by the power sectors for real-time measurements with phasor measurement unit (PMU) as the main elemental device. Industries developing PMUs must ensure that it should comply the IEEE C37.118.1-2011 and C37.118.1a-2014 synchrophasor standards, as the corrective action taken by power grid in real-time environment will depend on the PMU data. The optimization of PMU ensures that the measurement results are as per the IEEE synchrophasor standards leading to improvement in its performance. Here, we had evaluated the performance of an industrial PMU using CSIR-NPL PMU calibration system. The evaluation was done under static and dynamic conditions. This analysis represents the capability of PMU testing and calibration at CSIR-NPL and also ensures that the PMU that will be used in real time on the fields reports precise data. PMU-Cal facility can handle all the steady-state and dynamic-state tests for both M class and P class configured PMU at all desired frame rates. This system is traceable to its respective primary standards and is functional to cater the needs of power sector in terms of PMU calibration and testing.
机译:技术改进和印度的新初创企业导致了电力需求的巨大增加。该网格正在进行智能,更高效可靠,不仅满足不断增长的能源需求,也可以防止停电。功率部门的同步技术正在进行,用于使用Phasor测量单元(PMU)作为主要元素装置的实时测量。开发PMU的行业必须确保它应该符合IEEE C37.118.1-2011和C37.118.1A-2014同步素标准,因为电网在实时环境中采取的纠正措施取决于PMU数据。 PMU的优化可确保测量结果根据IEEE同步素标准,导致其性能的提高。在这里,我们使用CSIR-NPL PMU校准系统评估了工业PMU的性能。评估是在静态和动态条件下进行的。该分析代表了PMU测试和CSIR-NPL校准的能力,并确保了将实时使用的PMU在字段上报告精确的数据。 PMU-CAL设施可以在所有所需帧速率下处理M类和P类配置PMU的所有稳态和动态状态测试。该系统可追溯到其各自的主要标准,并且在PMU校准和测试方面具有迎合电力部门的需求。

著录项

  • 来源
    《Trends in Ecology & Evolution》 |2020年第1期|共8页
  • 作者单位

    CSIR Natl Phys Lab LF HF Voltage Current &

    Microwave Metrol 120 Metrology Bldg Dr KS Krishnan Marg New Delhi 110012 India;

    CSIR Natl Phys Lab LF HF Voltage Current &

    Microwave Metrol 120 Metrology Bldg Dr KS Krishnan Marg New Delhi 110012 India;

    CSIR Natl Phys Lab LF HF Voltage Current &

    Microwave Metrol 120 Metrology Bldg Dr KS Krishnan Marg New Delhi 110012 India;

    CSIR Natl Phys Lab LF HF Voltage Current &

    Microwave Metrol 120 Metrology Bldg Dr KS Krishnan Marg New Delhi 110012 India;

    CSIR Natl Phys Lab LF HF Voltage Current &

    Microwave Metrol 120 Metrology Bldg Dr KS Krishnan Marg New Delhi 110012 India;

    CSIR Natl Phys Lab LF HF Voltage Current &

    Microwave Metrol 120 Metrology Bldg Dr KS Krishnan Marg New Delhi 110012 India;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 数学生态学与生物模型;
  • 关键词

    Calibration; PMU; Smart grid; Synchrophasor; Traceability;

    机译:校准;PMU;智能电网;同步素;可追溯性;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号