In this investigation, nucleate boiling heat transfer coefficients and dynamic contact angle were experimentally measured during pool boiling of water on a horizontal heating rod in heat flux range between 1-120 kW m~(-2) under atmospheric pressure. Experiments were performed at several degrees of surface roughness ranging between 3 and 43 μm average vertical deviation. The results showed that dynamic contact angle is increased with increased heat flux and surface roughness. A new model is proposed to predict Stanton dimensionless number by employing dimensional analysis. This model has <2% absolute error.
机译:在该研究中,在水平加热棒的水平加热棒在大气压下的热通量范围内的水平加热棒中进行实验测量核心沸腾的传热系数和动态接触角。 实验在平均垂直偏差3至43μm的几个表面粗糙度下进行。 结果表明,随着热通量和表面粗糙度增加,动态接触角增加。 提出了一种通过使用尺寸分析来预测Stanton维度数的新模型。 此模型的绝对错误具有<2%。