The slurry sampling technique has been applied for the determination of As, Cd, and Pb in mainstream cigarette smoke condensate (MS CSC) by graphite furnace-atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS). The MS CSC of the 1R4F Reference Cigarette was collected by electrostatic precipitation and was subsequently prepared as two slurry samples with and without the dispersing agent Triton X-100. Comparison of results determined by ICP-MS analyses of the 1R4F MS CSC slurry samples with those from the conventional microwave digestion method revealed good agreement. The precision of Triton X-100 slurry sampling and of microwave-as-sisted digestion was better than 10% RSD, and both were superior to slurry sampling without use of Triton X-100. The accuracy of the analytical results for the Triton X-100 slurry sample was further verified by graphite furnace-atomic absorption spectrometry (GF-AAS). For GF-AAS, the method limits of detection are 1.6, 0.04, and 0.5 μg L~(-1) for s, Cd, and Pb, respectively. For ICP-MS, the method limits of detection are 0.06, 0.01, and 0.38 μg L~(-1) for As, Cd, and Pb, respectively. The MS CSC of the 1R4F Reference Cigarette was collected in accordance with the Federal Trade Commission (FTC) smoking regime (35 mL puff volume of 2-s puff duration at an interval of 60 s) and the concentrations of As, Cd and Pb were 6.0±0.5, 69.3±2.8, and 42.0±2.1 ng/cigarette, respectively.
机译:浆液采样技术已通过石墨炉原子吸收光谱法(ICP-MS)和电感耦合等离子体质谱法(ICP-MS)被用于测定主流香烟烟雾冷凝物(MS CSC)中的As,Cd和Pb 。通过静电沉淀法收集1R4F参比香烟的MS CSC,然后将其制备为有和没有分散剂Triton X-100的两个浆液样品。通过ICP-MS分析1R4F MS CSC浆料样品与常规微波消解方法得到的结果进行比较,结果显示出良好的一致性。 Triton X-100泥浆采样和微波辅助消解的精度优于10%RSD,两者均优于不使用Triton X-100的泥浆采样。 Triton X-100浆料样品的分析结果的准确性通过石墨炉原子吸收光谱法(GF-AAS)进一步证实。对于GF-AAS,s,Cd和Pb的检测限分别为1.6、0.04和0.5μgL〜(-1)。对于ICP-MS,砷,镉和铅的检测限分别为0.06、0.01和0.38μgL〜(-1)。根据联邦贸易委员会(FTC)吸烟制度(35毫升抽吸量2s抽吸间隔60秒)收集1R4F参考香烟的MS CSC。分别为6.0±0.5、69.3±2.8和42.0±2.1 ng /支。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号