首页> 外文期刊>Experimental Thermal and Fluid Science: International Journal of Experimental Heat Transfer, Thermodynamics, and Fluid Mechanics >Fast response transient behaviour of a coaxial thermal probe and recovery of surface heat flux for shock tube flows
【24h】

Fast response transient behaviour of a coaxial thermal probe and recovery of surface heat flux for shock tube flows

机译:同轴热探针的快速响应瞬态行为及休克管流动表面热通量回收

获取原文
获取原文并翻译 | 示例
           

摘要

The magnitude of surface heat flux and its accurate estimation are very crucial owing to their applicability in impulsive thermal loads for high-speed flights. The correctness of such heat flux is associated with the implications from highly responsive thermal sensors in ground-based aerodynamic studies. In the present study, the performance effectiveness of an indigenous, in-house-made coaxial thermal probe (CTP) is validated against a standard silver thin film gauge (TFG) counterpart. The thermal probe has been fabricated in-house from two metal alloys; chromel (3.25 mm diameter and 10 mm length) and constantan (0.91 mm diameter and 15 mm length), by disposing one in the annulus of another coaxially, subsequently clubbed by a thin layer of epoxy in between them. Similarly, the thin film gauge is fabricated by putting silver paste (similar to 1 mu m thickness) on the pyrex substrate (3.25 mm diameter, 10 mm length). The fabrication process is followed by different calibration activities to determine the characteristics constants for sensors (sensitivity, thermal product value for CTP, and temperature coefficient of resistance for TFG). Both the probes are tested in a highly transient environment in a shock tube that generates high density, high pressure, and high enthalpy flows. The response time of the CTP and TFG are found to be 265 mu s and 240 mu s, respectively. The heat flux values estimated through temperature responses are having a nice match for CTP as well as TFG with a deviation in peak heat flux value within a range of +/- 2%. A similar trend and magnitude are also re-assured through numerical simulation within an uncertainty band of +/- 1.5%. The exhaustive study carried out in a shock tube has assured the performance and reliability of a CTP. Hence, it is recommended as an effective heat flux sensor for routine measurements in impulsive heat loadings.
机译:None

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号