首页> 外文期刊>Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine >Application of GESPECOR software for the calculation of coincidence summing effects in special cases.
【24h】

Application of GESPECOR software for the calculation of coincidence summing effects in special cases.

机译:GESPECOR软件在特殊情况下的巧合求和效果计算中的应用。

获取原文
获取原文并翻译 | 示例
           

摘要

In this work, coincidence summing correction factors have been measured for (133)Ba, (152)Eu and (88)Y point sources with a 50% relative efficiency p-type detector and a 25% relative efficiency n-type detector in two close-to-detector measurement geometries. The experimental data for (133)Ba and (152)Eu and the results obtained with the GESPECOR software reveal a complex structure of the conventional dead layer of the p-type detector. The high value of the coincidence summing correction factor for the 511keV peak of (88)Y, in agreement with the values computed by GESPECOR, in this case cautions against the application of the semiempirical method for evaluating coincidence summing effects.