首页> 外文期刊>Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine >Standardization of ↑(139)Ce by the Liquid Scintillation Counting using the Triple to Double Coincidence Ratio Method
【24h】

Standardization of ↑(139)Ce by the Liquid Scintillation Counting using the Triple to Double Coincidence Ratio Method

机译:三次重合比法通过液体闪烁计数法对↑(139)Ce的标准化

获取原文
获取原文并翻译 | 示例
           

摘要

A good agreement of the results of standardization of ↑(139)Ce by the TDCR method using RC and LPRI LS-counters was obtained. The results were confirmed by the 4πβ (LS)-λ, coincidence, 4πγ(NaI), 4πβ (PC)-γ, coincidence and X and I, spectrometer methods. The detection efficiency determination was improved by calculation of the Compton effect scintillation spectrum including the scattered photons events.A substantial modification of the TDCR method was introduced by a new parameter K3 = 132L纽?ε↑(3)↓(D) being the triple to double in third power counting efficiency ratio.#1998 Elsevier Science Ltd. All rights reserved
机译:使用RC和LPRI LS计数器通过TDCR方法获得的↑(139)Ce标准化结果获得了很好的一致性。结果由4πβ(LS)-λ,重合,4πγ(NaI),4πβ(PC)-γ,重合以及X和I分光光度计方法确认。通过计算包括散射光子事件的康普顿效应闪烁光谱提高了检测效率的确定。TDCR方法的实质性改进是引入了新的参数K3 =132L纽?ε↑(3)↓(D)。第三功率计数效率比提高三倍。#1998 Elsevier Science Ltd.保留所有权利