摘要

The paper presents the outcomes of existing conflicting views between the structural and geotechnical engineers about the approach to assessing an existing wharf retaining structure at Flinders Port, Adelaide. It demonstrates that working together is the only way to obtain a 'best for client' engineering solution. The paper summarises geotechnical analysis outputs for structural capacity assessment. Analysis indicates that new crane loads will have a negligible effect on the current Factor of Safety (FOS) for the overall geotechnical stability of the berth. Additional vertical crane loads only affect the vertical load on sheet piles and have little influence on geotechnical and structural capacity against rotational or translation movement.
机译:本文介绍了结构和岩土工程师之间关于评估阿德莱德弗林德斯港现有码头固定结构方法的现有观点存在冲突的结果。它表明,携手合作是获得“最佳客户”工程解决方案的唯一途径。本文总结了用于结构能力评估的岩土分析结果。分析表明,对于整个泊位的岩土工程稳定性,新的起重机负载对当前的安全系数(FOS)的影响可忽略不计。附加的垂直起重机载荷仅影响板桩的垂直载荷,而对岩土和结构抵抗旋转或平移运动的能力影响很小。