首页> 外文期刊>British journal of ophthalmology >MICS with toric intraocular lenses in keratoconus: Outcomes and predictability analysis of postoperative refraction
【24h】

MICS with toric intraocular lenses in keratoconus: Outcomes and predictability analysis of postoperative refraction

机译:圆锥角膜复曲面人工晶状体的MICS:术后屈光的结果和可预测性分析

获取原文
获取原文并翻译 | 示例
           

摘要

Aims: To investigate the visual and refractive outcomes, safety, efficacy and stability of cataract surgery in eyes with stable keratoconus. Methods: 17 eyes (10 patients) diagnosed as stable keratoconus, aged from 34 to 73 years (56.63±12.47), underwent micro-incision cataract surgery (MICS) followed by implantation of toric intraocular lens (IOL). Seven of them were operated bilaterally and three unilaterally. A complete ophthalmological examination was performed preoperatively and postoperatively. The main outcome measures were: uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry and manifest refraction. Results: Sphere changed from -1.77±6.57D (-11.00 to 7.00) preoperatively to 0.08±0.79D (-1.25 to 1.75) postoperatively ( p=0.211), and cylinder changed from -2.95±1.71D (-7.00 to -0.75) to -1.40±1.13D (-3.25 to 0.00) ( p=0.016). UDVA (logMAR) changed from 1.33±0.95 (0.40 to 2.77) to 0.32±0.38 (0.00 to 1.30) ( p=0.008) and CDVA (logMAR) changed from 0.32±0.45 (0.01 to 1.77) to 0.20±0.36 (-0.03 to 1.30) ( p=0.013). Efficacy and safety indexes were 1.38 ±0.58 and 1.17±0.66, respectively. Refraction and corneal topography were stable during the follow-up (9.10±5.54 months, 3-15) Conclusions: MICS surgery using corneal topography data and standard formulas for the calculation of the IOL power is a safe and effective procedure regarding keratometric stability, visual and refractive results.
机译:目的:研究具有稳定圆锥角膜的白内障手术的视觉和屈光效果,安全性,有效性和稳定性。方法:17眼(10例患者)被诊断为圆锥角膜稳定,年龄从34岁至73岁(56.63±12.47),接受微切口白内障手术(MICS),然后植入复曲面人工晶状体(IOL)。其中有七个是双边手术,三个是单方面手术。术前和术后进行了全面的眼科检查。主要结局指标为:未矫正远视力(UDVA),矫正远视力(CDVA),角膜曲率法和明显屈光度。结果:术前球体从-1.77±6.57D(-11.00变为7.00)变为术后0.08±0.79D(-1.25〜1.75)(p = 0.211),圆柱体从-2.95±1.71D(-7.00变为-0.75) )至-1.40±1.13D(-3.25至0.00)(p = 0.016)。 UDVA(logMAR)从1.33±0.95(0.40到2.77)变为0.32±0.38(0.00到1.30)(p = 0.008)和CDVA(logMAR)从0.32±0.45(0.01到1.77)变为0.20±0.36(-0.03)至1.30)(p = 0.013)。疗效和安全性指标分别为1.38±0.58和1.17±0.66。随访期间(9.10±5.54个月,3-15)屈光和角膜地形图是稳定的结论:使用角膜地形图数据和标准公式计算IOL屈光力的MICS手术对于角膜曲率稳定性,视觉检查是安全有效的程序和屈光结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号