首页> 外文期刊>International Journal of Refrigeration >An experimental investigation of refrigerant mixture R32/R290 as drop-in replacement for HFC410A in household air conditioners
【24h】

An experimental investigation of refrigerant mixture R32/R290 as drop-in replacement for HFC410A in household air conditioners

机译:R32 / R290混合制冷剂替代家用空调中HFC410A的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

In the present paper, the refrigerant mixture R32/R290 (68%/32% by weight) is investigated as the drop-in replacement for R410A in household air conditioners. The GWP of it is only 22% of that of R410A. Theoretical and experimental investigations are conducted on the performance of the air conditioners working with both R32/R290 and R410A. Experimental results show that the refrigerant charge amount of R32/R290 is reduced by 30.0%-35.0%; the cooling and heating capacities are increased by 14.0%-23.7%. For further reducing charge amount and flammability, the micro-channel heat exchanger (condenser) is employed to replace the finned tube one. Compared with the R32/R290 system using finned tube heat exchanger, the R32/R290 charge amount and the power consumption are reduced by 34.1% and 0.4%, respectively; the cooling capacity and the COP are increased by 6.4% and 6.8%, respectively. (C) 2015 Elsevier Ltd and IIR. All rights reserved.
机译:在本文中,研究了制冷剂混合物R32 / R290(按重量计占68%/ 32%)作为家用空调中R410A的直接替代品。它的全球升温潜能值仅为R410A的22%。对使用R32 / R290和R410A的空调的性能进行了理论和实验研究。实验结果表明,R32 / R290的制冷剂充注量降低了30.0%-35.0%;制冷和制热能力提高了14.0%-23.7%。为了进一步减少装料量和可燃性,采用微通道热交换器(冷凝器)代替翅片管。与使用翅片管热交换器的R32 / R290系统相比,R32 / R290的充电量和功耗分别减少了34.1%和0.4%;制冷能力和COP分别提高了6.4%和6.8%。 (C)2015 Elsevier Ltd和IIR。版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号