Effectiveness Evaluation of the Fat Percentage Determination in Multi-Echo T2-Corrected Single-Voxel Spectroscopy by Comparing the 3-Point Dixon and the 6-Point Interference Dixon Techniques

机译:比较三点狄克逊和六点干涉狄克逊技术测定多回波T2校正单体素光谱中脂肪百分比的有效性

获取原文
获取原文并翻译 | 示例
           

摘要

This study compared fat percentage in the HISTO method and chemical-shift imaging method, a 3-echo 3D gradient echo sequence with a T2*-corrected Dixon (3-point Dixon) and 6-echo interference Dixon magnetic resonance (MR) imaging (6-point Dixon) method, to evaluate clinical significance of fatty liver quantification by multi-echo T2*-corrected single-voxel spectroscopy Histo (HISTO). A total of 21 liver donors underwent MR imaging examination. The 3-T MR system (Siemens Healthcare Tim Verio, Erlangen, Germany) was used for all studies. For fat percentage evaluations, a 3-echo 3D gradient echo sequence with T2*-corrected Dixon (3-point Dixon) and 6-Echo Interference Dixon (6-point Dixon) pulse sequences, including HISTO, were applied in sequence. Using fat percentages obtained from each pulse sequence, levels of fatty liver were classified as: non-fatty liver, < 5 %; mild fatty liver, > 5 but < 31 %; and severe fatty liver, > 31 %. The correlation between methods was calculated with a correlation coefficient (R (2)): HISTO and 3-point Dixon, 0.936 (p < 0.001); HISTO and 6-point Dixon, 0.944 (p < 0.001); and 3-point Dixon and 6-point Dixon, 0.984 (p < 0.001). The HISTO, which was used to investigate fat percentages after T2* correction, showed a high correlation with 3-point Dixon and 6-point Dixon, suggesting that the multi-echo method is useful for accurately determining fat percentages.
机译:这项研究比较了HISTO方法和化学位移成像方法,3回波3D梯度回波序列与T2 *校正的Dixon(3点Dixon)和6回波干扰Dixon磁共振(MR)成像( 6点Dixon)方法,通过多回波T2 *校正的单体素光谱组织学(HISTO)评估脂肪肝定量的临床意义。共有21位肝捐赠者接受了MR成像检查。所有研究均使用3-T MR系统(Siemens Healthcare Tim Verio,德国埃尔兰根)。为了评估脂肪百分比,依次应用了具有T2 *校正的Dixon(3点Dixon)和6-Echo Interference Dixon(6点Dixon)脉冲序列(包括HISTO)的3回波3D梯度回波序列。使用从每个脉冲序列获得的脂肪百分比,将脂肪肝的水平归类为:非脂肪肝,<5%;轻度脂肪肝,> 5但<31%;重度脂肪肝,> 31%。方法之间的相关性通过相关系数(R(2))计算:HISTO和3点Dixon,0.936(p <0.001); HISTO和6点Dixon,0.944(p <0.001); 3点Dixon和6点Dixon,0.984(p <0.001)。用于校正T2 *后的脂肪百分比的HISTO与3点Dixon和6点Dixon具有高度相关性,这表明多回波法可用于准确确定脂肪百分比。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号