The analytical performances of the developed sensor were evaluated in laboratory for the semicontinuous monitoring of Cd and Ph in water samples at mu g L-1 level. The effects of oxygen, pH, and stirring on the voltammetric response of these metals were investigated. The O-2 removal did not allow to improve the peak current. In return, stirring appeared indispensable to avoid the impoverishment of metals in the diffusion layer. The necessity to control the pH and the solution evolution in laboratory experiments was also clearly established. The semicontinuous monitoring of Cd and Ph was then performed for 42 h in tap water and demonstrated that sensor is a promised tool for semicontinuous environmental analyses.
机译:在实验室中对开发的传感器的分析性能进行了评估,以半连续监测μg L-1水平下的水样中的Cd和Ph。研究了氧气,pH和搅拌对这些金属的伏安响应的影响。 O-2的去除不允许提高峰值电流。作为回报,为了避免扩散层中金属的贫化,搅拌似乎是必不可少的。还明确确立了在实验室实验中控制pH值和溶液演变的必要性。然后在自来水中对Cd和Ph进行半连续监测42 h,并证明传感器是用于半连续环境分析的有前途的工具。