首页> 外文期刊>Experimental Thermal and Fluid Science: International Journal of Experimental Heat Transfer, Thermodynamics, and Fluid Mechanics >Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure
【24h】

Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure

机译:小直径螺旋盘管在低压下的过冷和饱和水流沸腾压降

获取原文
获取原文并翻译 | 示例
           

摘要

Experimental pressure drop results on boiling water flow through three helical coils of tube inner diameter of 4.03 mm and 4.98 mm and coil diameter to tube diameter ratio of 26.1, 64.1 and 93.3 are presented. Both subcooled and saturated flow boiling are investigated, covering operating pressures from 120 to 660 kPa, mass fluxes from 290 to 690 kg m(-2) s(-1) and heat fluxes from 50 to 440 W m(-2). Existing correlations for subcooled flow pressure drop are found not capable to fit the present subcooled database, while the measurements in saturated flow conditions are successfully reproduced by existing correlations for both straight and coiled pipe two-phase flow. The experimental database is included in tabular form. (c) 2008 Elsevier Inc. All rights reserved.
机译:给出了沸腾水流经三个螺旋形盘管的实验压降结果,三个盘管的内径分别为4.03 mm和4.98 mm,盘管直径与管径之比为26.1、64.1和93.3。研究了过冷沸腾和饱和流沸腾,涵盖了120至660 kPa的工作压力,290至690 kg m(-2)s(-1)的质量通量和50至440 W m(-2)的热通量。发现过冷流量压降的现有相关性无法适应当前的过冷数据库,而饱和流量条件下的测量值已通过直管和盘管两相流的现有相关性成功复制。实验数据库以表格形式包括在内。 (c)2008 Elsevier Inc.保留所有权利。