首页> 外文期刊>Flow Measurement and Instrumentation >The location of temperature sensors in pipe flows for determining the mean gas temperature in flow metering applications
【24h】

The location of temperature sensors in pipe flows for determining the mean gas temperature in flow metering applications

机译:温度传感器在管道中的位置,用于确定流量计量应用中的平均气体温度

获取原文
获取原文并翻译 | 示例
           

摘要

The work presented here is intended to indicate the optimum insertion depth of temperature probes used in natural gas pipe flows. Other influences as material layers in the protective pipe, working pressures and pipe wall temperatures are studiedas well and recommendations for the optimum insertion depth are derived. Computational Fluid Dynamics (CED) on a 3D model using FLUENT 4.32 predicts the temperature with very little deviation from measurements. CFD proves to be a very powerful instrumentfor a quantitative analysis of flow meter instrumentation.
机译:本文介绍的工作旨在表明天然气管道流量中使用的温度探头的最佳插入深度。还对保护管中的材料层,工作压力和管壁温度等其他影响进行了研究,并得出了最佳插入深度的建议。使用FLUENT 4.32的3D模型上的计算流体动力学(CED)可以预测温度,而与测量值的偏差很小。 CFD被证明是对流量计仪表进行定量分析的一种非常强大的工具。