首页> 外文期刊>Canadian journal of anesthesia: Journal canadien d'anesthesie >A reusable, custom-made warming blanket prevents core hypothermia during major neonatal surgery: (Une couverture chauffante reutilisable, faite sur mesure, previent l'hypothermie centrale pendant une intervention chirurgicale neonatale importante).
【24h】

A reusable, custom-made warming blanket prevents core hypothermia during major neonatal surgery: (Une couverture chauffante reutilisable, faite sur mesure, previent l'hypothermie centrale pendant une intervention chirurgicale neonatale importante).

机译:可重复使用的定制保暖毯可防止大型新生儿手术期间的核心体温过低:可重复使用的定制保暖毯可防止大型新生儿手术期间的中央体温过低。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To introduce a reusable model of neonatal forced air warming blanket for intraoperative use during major noncardiac neonatal surgery and to determine clinical efficacy of this reusable blanket compared with the commonly used disposable blankets. METHODS: Delivered air temperature and calorie uptake of standard thermal bodies within the reusable blankets, Bair Hugger(R) blanket model 530 and model 555 were studied. Also, an efficacy study was conducted in 90 neonatal patients scheduled for major noncardiac surgery comparing the reusable blanket, the Bair Hugger(R) blanket model 530 and passive heat conservation as a control. The covered reusable blanket was used as a rescue procedure if the core temperature was < 35.5 degrees C. RESULTS: Delivered air temperature and heat transfer from the covered reusable blanket did not differ significantly from those of the Bair Hugger(R) blanket model 530 and model 555 (despite 0.75 degrees C-1.2 degrees C of heat trapped under the sheet and 1.3 Kcal less energy transfer). Temperatures measured underneath patients (correlated to poorly perfused areas) were highest using the Bair Hugger(R) blanket model 555. The reusable blanket was efficacious in preventing intraoperative core hypothermia and not different from the Bair Hugger(R) blanket model 530. About 1/3 of the patients in the control group had presented a core temperature < 35.5 degrees C but were successfully rescued using the reusable blanket. No adverse events were associated with any of these warming methods. CONCLUSION: This study shows the clinical efficacy of our reusable blanket for the prevention of core hypothermia during major neonatal surgery, which is not different from commonly used disposable blankets.
机译:目的:介绍一种可重用的新生儿强制性空气暖和毯模型,用于在非心脏非主要新生儿手术中术中使用,并确定该可重复使用的毯子与常用一次性毯子相比的临床疗效。方法:研究了可重复使用的毯子中标准热量的输送空气温度和卡路里吸收量,研究了Bair Hugger(R)毯子型号530和555型。同样,在计划进行大型非心脏手术的90例新生儿患者中进行了一项功效研究,比较了可重复使用的毯子,BairHugger®毯子模型530和被动保温作为对照。如果中心温度低于35.5摄氏度,则将覆盖的可重复使用的毯子用作救援程序。结果:从覆盖的可重复使用的毯子传递的空气温度和传热与530型Bair Hugger(R)毯子和555型(尽管在板下捕获了0.75摄氏度至1.2摄氏度的热量,但能量传递少了1.3千卡)。使用555型BairHugger®毯子模型,在患者下方测得的温度(与灌流不良区域相关)最高。可重复使用的毯子可有效防止术中核心体温过低,与530型的BairHugger®毯子模型没有区别。约1对照组中有3名患者的中心温度低于35.5摄氏度,但使用可重复使用的毯子成功将其救出。这些升温方法均无不良事件发生。结论:这项研究表明我们可重复使用的毯子在大型新生儿手术中预防核心体温过低的临床疗效,与常用的一次性毯子没有什么不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号