PURPOSE: To determine the needle size that would consistently enable the pathologist to correctly diagnose tissue core biopsy specimens. MATERIALS AND METHODS: Fifty-seven surgically removed mass lesions of the breast were sampled with a short-throw automated biopsy gun and an 18-gauge needle first, followed by a 16- and a 14-gauge needle. Samples were evaluated independently by three pathologists, and findings were compared with the final diagnosis made at surgical excision biopsy. RESULTS: The sensitivity for the diagnosis of all 26 malignant lesions was 100%, 92%, and 65% for biopsy samples obtained with 14-, 16-, and 18-gauge needles, respectively. Specificity for malignancy was 100% for all three needle sizes. All of the benign diseases were correctly diagnosed in samples obtained with all three size needles except for two samples that did not survive processing. CONCLUSION: Biopsy samples obtained with a 14-gauge needle provide the most accurate diagnosis, which correlates with the diagnosis madewith the surgical excision biopsy technique.
机译:目的:确定能够使病理学家正确诊断组织核心活检标本的针头尺寸。材料与方法:对57例经手术切除的乳腺肿块病变进行了取样,首先使用短程自动活检枪和18号针头,然后是16号和14号针头。由三名病理学家对样品进行独立评估,并将发现的结果与手术切除活检的最终诊断结果进行比较。结果:对于使用14针,16针和18针的活检样本,诊断所有26例恶性病变的敏感性分别为100%,92%和65%。所有三种针头尺寸的恶性特异性均为100%。在所有三个尺寸的针头获得的样品中,除了两个无法在加工后存活的样品外,所有良性疾病均已正确诊断。结论:用14号针头获得的活检样品提供了最准确的诊断,这与手术切除活检技术做出的诊断有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号