Patient kerma-area product P-KA, cumulative kerma in the air K-IRP, fluoroscopic time t, personal dose equivalent (in terms of Hp(10), Hp(0.07) and Hp(3)) for most common interventional cardiology procedures were measured. P-KA and K-IRP measurements were used for patients and thermoluminescent dosimetry for the personnel. Dosemeters for personal doses measurements containing MCP-N (LiF: Mg, Cu, P) type thermoluminescence detectors (TLDs), were read out at the Institute of Nuclear Physics Polish Academy of Science (IFJ PAN) dosimetry service.