Objective: To evaluate T2* values in various histological severities of osteoarthritis (OA). Method: Magnetic resonance imaging (MRI) and T2* mapping including a three-dimensional (3D) double-echo steady-state (DESS) sequence for morphological cartilage assessment and a 3D multiecho data image combination (MEDIC) sequence for T2* mapping were conducted in 21 human femoral head specimens with varying severities of OA. Subsequently, histological assessment was undertaken in all specimens to correlate the observations of T2* mapping with histological analyses. According to the Mankin score, four grades of histological changes were determined: grade 0 (Mankin scores of 0-4), grade I (scores of 5-8), grade II (scores of 9-10), and grade III (scores of 11-14). For reliability assessment, cartilage T2* measurements were repeated after 4 weeks in 10 randomly selected femoral head specimens. Results: T2* values decreased significantly with increasing cartilage degeneration (total . P-values <0.001) ranging from 36.3 ± 4.3 ms in grade 0 regions to 22.8 ± 4.3 ms in regions with grade III changes. Pearson correlation analysis proved a fair correlation between T2* values and Mankin score (correlation coefficient = -0.362) that was statistically significant (. P-value <0.001). Intra-class correlation (ICC) analysis demonstrated high intra-observer reproducibility for the T2* measurement (ICC: 0.949, . P < 0.001). Conclusions: Given the advantages of the T2* mapping technique with no need for contrast medium, high image resolution and ability to perform 3D biochemically sensitive imaging, T2* mapping may be a strong addition to the currently evolving era of cartilage biochemical imaging.
机译:目的:评估各种组织学严重程度骨关节炎(OA)中的T2 *值。方法:磁共振成像(MRI)和T2 *映射包括用于形态软骨评估的三维(3D)双回波稳态(DESS)序列和用于T2 *映射的3D多回波数据图像组合(MEDIC)序列在21例不同严重程度的OA的人股骨头样本中进行。随后,对所有标本进行组织学评估,以将T2 *作图的观察结果与组织学分析相关联。根据Mankin评分,确定了四个组织学变化等级:0级(Mankin评分为0-4),I级(评分为5-8),II级(评分为9-10)和III级(评分) 11-14)。为了进行可靠性评估,在10个随机选择的股骨头标本中,在4周后重复进行软骨T2 *测量。结果:T2 *值随着软骨变性的增加而显着降低(总P值<0.001),范围从0级36.3±4.3 ms到III级变化22.8±4.3 ms。皮尔逊相关分析证明T2 *值与Mankin评分(相关系数= -0.362)之间具有合理的相关性,具有统计学意义(。P值<0.001)。类内相关性(ICC)分析表明,观察者对T2 *的测量具有较高的可重复性(ICC:0.949,。P <0.001)。结论:鉴于T2 *映射技术的优势,不需要造影剂,高图像分辨率和执行3D生化敏感成像的能力,T2 *映射可能是当前软骨生化成像时代的有力补充。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号