Amniotic lamellar body counts determined with the Sysmex XE-2100 analyzer to predict fetal lung maturity during diabetic and other complicated pregnancies.

机译:用Sysmex XE-2100分析仪确定的羊膜层计数,可预测糖尿病和其他复杂妊娠期间胎儿肺的成熟度。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The detection of amniotic lamellar bodies (LB) has been shown to be a rapid and simple way to assess fetal lung maturity (FLM). The maturity thresholds for LB vary due to different factors, one being the type of particle-count analyser used. MATERIAL AND METHODS: The Sysmex XE-2100 hematological analyser was evaluated in determination of amniotic LB counts and compared with lecithin/sphingomyelin (L/S) and phosphatidylglycerol (PG) determination. We analysed 132 amniotic samples from a total of 109 mothers (71 diabetic) with 112 infants. Results. The correlation between the LB counts obtained with the Sysmex XE-2100 and our reference thin layer chromatography (TLC) phospholipid method was good. Samples with low L/S ratio (< or = 2.0) and no PG (i.e. premature fetal lung status), had low LB counts (n = 18, mean 8500/L, range 1000-26000), whereas 51 samples with mature fetal lung status had high LB counts (mean 63600/uL, range 20,000-139,000). In all our four cases of respiratory distress syndrome the LB counts were low (range 1000-28000/uL). The reference values for FLM determination were established: < or = 6000/microL for immature, values between 7000 and 35,000/uL for borderline results and >35,000/uL for mature. CONCLUSIONS. The amniotic LB count analysis with Sysmex XE-2100 has many advantages being a repeatable, inexpensive and quantitative method with a very short turn-around time. Consequently, our routine is to perform LB counts initially from all amniotic samples and only borderline LB results are analysed with TLC.
机译:目的:检测羊膜层状体(LB)是评估胎儿肺成熟度(FLM)的快速简便的方法。 LB的成熟度阈值因不同因素而有所不同,一种是所使用的颗粒计数分析仪的类型。材料与方法:对Sysmex XE-2100血液分析仪进行了羊水LB计数测定,并与卵磷脂/鞘磷脂(L / S)和磷脂酰甘油(PG)测定进行了比较。我们分析了总共109名母亲(71名糖尿病患者)和112名婴儿的132个羊膜样品。结果。用Sysmex XE-2100和我们的参考薄层色谱(TLC)磷脂方法获得的LB计数之间的相关性很好。 L / S比低(<或= 2.0)且无PG(即胎肺早熟)的样本LB计数低(n = 18,平均8500 / L,范围1000-26000),而51例具有成熟胎儿肺部状态具有较高的LB计数(平均63600 / uL,范围20,000-139,000)。在我们所有的四例呼吸窘迫综合征中,LB计数都很低(范围1000-28000 / uL)。确定FLM的参考值:未成熟度≤6000 /μL,临界结果≤7000至35,000 / uL,成熟度≥35,000 / uL。结论。使用Sysmex XE-2100进行的羊膜LB计数分析具有许多优点,它是一种可重复,廉价且定量的方法,具有非常短的周转时间。因此,我们的常规工作是首先从所有羊膜样本中进行LB计数,并且仅使用TLC分析临界的LB结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号