The report is dedicated to the results of AC-loss measurements in the ITER (International Thermonuclear Experimental Reactor) Nb3Sn strand and ITER design subsize cable samples. The test facility described below includes the set of superconducting magnet systems furnished with boil-off calorimetric inserts and calorimetric schemes including gas-flow meters. The calorimetric method and the magnetization loop recording method were used simultaneously for the AC-loss measurements. The coincidence between the results of both measuring techniques was confirmed. The original calorimetric scheme makes it possible to measure the released energy during one pulse of the magnet field. The results of AC loss measurements in ITER subsize conductor samples manufactured in Russia are given as an example. (C) 1998 Elsevier Science B.V. All rights reserved. [References: 3]
机译:该报告专门针对ITER(国际热核实验反应堆)Nb3Sn绞线和ITER设计尺寸较小的电缆样本中的交流损耗测量结果。下文所述的测试设备包括一组超导磁体系统,这些系统配有沸腾的量热插件和包括气体流量计在内的量热方案。量热法和磁化回路记录法同时用于交流损耗测量。两种测量技术的结果之间的一致性得到了证实。原始的量热方案可以测量一个磁场脉冲期间释放的能量。以俄罗斯制造的ITER小尺寸导体样品中的交流损耗测量结果为例。 (C)1998 Elsevier Science B.V.保留所有权利。 [参考:3]