首页> 美国政府科技报告 >Intrinsic Remediation Engineering Evaluation/Cost Analysis Addendum for UST Site 870, Hill Air Force Base Ogden, Utah
【24h】

Intrinsic Remediation Engineering Evaluation/Cost Analysis Addendum for UST Site 870, Hill Air Force Base Ogden, Utah

机译:UsT site 870,犹他州奥格登山空军基地的内在修复工程评估/成本分析附录

获取原文

摘要

The intent of the EE/CA Addendum was to determine the role of natural attenuation in remediating fuel contamination in groundwater at Site 870. The EE/CA was conducted to evaluate the use of intrinsic remediation with long-term monitoring (LTM) for remediation of fuel hydrocarbon contamination dissolved in groundwater at UST Site 870. This update summarizes the results of the third sampling event performed as part of long-term groundwater monitoring at the site. The original EE/CA sampling event was conducted in August 1993 with the first long-term sampling occurring in July 1994 and the second long-term sampling occurring in September 1995. The main emphasis of this summary is to evaluate changes in dissolved benzene, toluene, ethylbenzene, and xylene (BTEX) concentrations, plume extent, and natural attenuation mechanisms through time.