首页> 美国政府科技报告 >Feasibility Study for the in Vivo Measurement of Lead in Bone Using L-X-Ray Fluorescence
【24h】

Feasibility Study for the in Vivo Measurement of Lead in Bone Using L-X-Ray Fluorescence

机译:L-X射线荧光法测定骨内铅含量的可行性研究

获取原文

摘要

Lead deposits in bone were detected by x-ray fluorescence using x-rays from either a exp 125 I or a exp 109 Cd source. Measurements were taken from tibia in intact human legs, post-mortem. On the basis of preliminary measurements, it was concluded that an exposure of one rad is adequate for determination of lead in bone. Both the advantages and the disadvantages of L-x-rays, used in the technique developed for this study, are compared with those of K-x-rays. (ERA citation 06:006466)