首页> 美国政府科技报告 >Modal Analysis for Structures with Foundation Interaction,
【24h】

Modal Analysis for Structures with Foundation Interaction,

机译:基础相互作用结构的模态分析,

获取原文

摘要

Three different analyses were performed on the following cases:rigid structures, a five-story building,and a fifteen-story building. Analyses included one in the frequency domain using the actual damping matrices CV and CH,providing what is referred to as 'exact'solution. In the second analysis normal modes were assumed,neglecting in effect the off-diagonal terms of matrices QTCVQ and QTCHQ. However,viscous and hysteretic damping terms were kept separate,and the solution was again obtained in the frequency domain. This solution is referred to as modal superposition in the frequency domain. Finally,in the third analysis a modal solution was obtained considering all the modal damping to be viscous. This is referred to as modal superposition in the time domain. The third type of analysis is the one which would be used in practice. Comparison of results for the first and second analyses shows the error introduced by assuming normal modes. Comparison of the second and third analyses shows the additional error introduced by replacing hysteretic modal damping by viscous modal damping. Comparison of the first and third solutions indicates the overall error resulting from use of weighted modal damping.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号