Mass Spectrometry: Residual Gas Analysis During Vacuum Melting

机译:质谱:真空熔炼过程中的残余气体分析

获取原文

摘要

A 180 deg magnetic deflection residual gas analyzer mass spectrometer with a mass range of 2 to 200 amu was used to study the nature of gases evolved during arc and electron-beam melting of certain reactive and refractory metals. The partial pressure of residual gases over molten Mo, Hf, Ti, and Fe, was found to be similar: Water and hydrogen were evolved from the samples and from the furnace components, carbon dioxide and carbon monoxide resulted from deoxidation of some of the melts. Argon and acetone were residuals in the system, and methane was a decomposed organic compound from the oil diffusion pump. (Author)