首页> 外文会议>International Conference on Environmental Systems >Development of the internal thermal control system (ITCS) for International Space Station (ISS)
【24h】

Development of the internal thermal control system (ITCS) for International Space Station (ISS)

机译:国际空间站内部热控制系统(ITC)的开发(ISS)

获取原文

摘要

The International Space Station (ISS) internal thermal control system (ITCS) has been developed jointly by the Boeing Corporation, Huntsville, Alabama, and Honeywell Engines & Systems, Torrance, California, to meet ISS internal thermal control needs. The ITCS provides heat removal for the critical life support systems and thermal conditioning for numerous experiment racks. The ITCS will be fitted on a number of modules on the ISS. The first module, the US Laboratory Module, was launched in February 2001 and is now operational on the ISS. The dual-loop system is comprised of a low-temperature loop (LTL) and a moderate-temperature loop (MTL). Each loop has a pump package assembly (PPA), a system flow control assembly (SFCA), a three-way mixing valve (TWMV), several rack flow control assemblies (RFCA), cold plates, pressure sensors, temperature sensors, a pump bypass assembly (PBA), and a heat exchanger. In addition, the MTL has an additional TWMV, a payload regeneration heat exchanger (P/RHE) and a manual flow control valve (MFCV). The LTL has a service performance and checkout unit (SPCU) heat exchanger. The two loops are linked via one loop crossover assembly (LCA) providing cross loop capabilities and a single-PPA two- loop functionality. Honeywell Engines & Systems performed extensive qualification testing at the component level. The Boeing Company performed the system level qualification testing. Details of the system testing and verification are contained in paper.
机译:国际空间站(ISS)内部热控制系统(ITCS)已由波音公司,亨茨维尔,阿拉巴马州和霍尼韦尔发动机和系统,加利福尼亚州托尔徒,加利福尼亚州,以满足ISS内部热控制需求。 ITCS为临界寿命支持系统和众多实验架的热调节提供了热量去除。 ITCS将适用于ISS的许多模块。 2001年2月推出的美国实验室模块的第一个模块,现在正在开展ISS。双环系统由低温环(LT1)和中等温度环(MTL)组成。每个环路都有一个泵封装组件(PPA),一个系统流量控制组件(SFCA),三通混合阀(TWMV),多个机架流量控制组件(RFCA),冷板,压力传感器,温度传感器,泵旁路组件(PBA)和热交换器。此外,MTL还具有额外的TWMV,有效载荷再生热交换器(P / RHE)和手动流量控制阀(MFCV)。 LTL具有服务性能和结帐单元(SPCU)热交换器。这两个循环通过一个环路交叉组件(LCA)链接,提供交叉循环能力和单PPA双循环功能。霍尼韦尔发动机和系统在组件级别进行了广泛的资格测试。波音公司进行了系统级资格测试。系统测试和验证的详细信息包含在纸中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号