Time-of-flight mass spectrometry offers unique advantages for the measurement of very short-lived exotic nuclei because of its short measurement cycle duration and its sensitivity. However, the mass resolving power of single-reflecting time-of-flight mass spectrometers (TOF-MS) is insufficient for the resolution of most isobaric radionuclides. To overcome this limitation, a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) has been developed, in which isobaric ions can be measured with a cycle time of about 1 ms. Applications of the MR-TOF-MS are envisaged for direct mass measurements and as a high-resolution mass separator at the in-flight facilities SHIP and FRS at GSI Darmstadt, Germany, at which short-lived exotic nuclei can be produced.
机译:飞行时间质谱仪由于其短测量循环持续时间及其灵敏度,为测量非常短的异国核来提供独特的优势。然而,单反反射飞行时间质谱仪(TOF-MS)的质量分辨能力不足以分辨大多数等异菌放射核素。为了克服这种限制,已经开发了多反射飞行时间质谱仪(MR-TOF-MS),其中可以用约1ms的循环时间测量等异构离子。 MR-TOF-MS的应用设想用于直接质量测量,并作为飞行中的高分辨率容量分离器,在德国GSI DAMSTADT的GSI Darmstadt的FRS,可以生产短寿命的外来核。