首页> 外文会议>International Congress on Arsenic in the Environment >The ACGIH Biological Exposure Index for urinary arsenic: To adjust for urinary creatinine or not?
【24h】

The ACGIH Biological Exposure Index for urinary arsenic: To adjust for urinary creatinine or not?

机译:泌尿砷的ACGIH生物暴露指数:调整尿肌酐或不适合何处?

获取原文

摘要

Employees at a Namibian Copper Smelter are occupationally exposed to inorganic arsenic as a contaminant of the complex ore concentrate being smelted and processed. Arsenic is monitored biologically by means of total urinary arsenic (uAs). The relationship between uncorrected uAs and creatinine corrected uAs (uAsCr) was examined for 4313 end of shift, end of week measurements with a view to understanding the impact of adjustment by urinary creatinine (uCr) concentration when comparisons are made with the American Conference of Governmental Industrial Hygienists (ACGIH) Biological Exposure Index (BEI). uAs and uAsCr were positively correlated. uAsCr provides a higher numerical value than uAs at uAs values below 25 μg/L, and a lower numerical value compared with uAs values above 25 μg/L, complicating comparisons with the uncorrected uAs ACGIH standard. The use of uncorrected uAs as required by the (ACGIH) can be misleading in both high and low exposure settings.
机译:纳米比亚铜冶炼厂的员工是职业上暴露于无机砷,作为复合矿石浓缩物的污染物被熔炼和加工。通过总尿砷(UAS)在生物学上监测砷。检查了未校正的UAS和肌酐校正UAS(USCR)的关系,检查了4313次班次,周末测量,以了解在与美国政府大会进行比较时,以了解尿肌酐(UCR)浓度调整的影响工业卫生师(ACGIH)生物曝光指数(BEI)。 uas和uascr是正相关的。 UASCR在低于25μg/ L的UAS值下提供比UA的更高的数值,以及与25μg/ L高于25μg/ L的UA值相比的数值,与未经校正的UAS ACGIH标准复杂化比较。根据(ACGIH)所需的未校正UAS可以在高曝光设置中误导。