首页> 外文会议>International Conference on Sustainable Energy, Environment and Information Engineering >Reason Analysis and Control Strategy on Operation Corrosion in Direct Air-cooled Condensers (ACC)
【24h】

Reason Analysis and Control Strategy on Operation Corrosion in Direct Air-cooled Condensers (ACC)

机译:直接风冷冷凝器操作腐蚀的原因分析与控制策略(ACC)

获取原文

摘要

The operation corrosion in direct air-cooled condensers (ACC) had been widespread in china. Various water treatment devices were used for condensate water in order to control feedwater iron concentration below the limit according to guidelines, however direct ACC operation corrosion still existed and needed a thorough solution. Ammonia has a lower partition coefficient in the initial condensate, as well acidic anions are concentrated in the initial condensate, thus the initial condensate has lower pH, which results in the above mentioned corrosion. To reduce the direct ACC operation corrosion, methods could be applied, such as dosing higher ammonia in feedwater or dosing some organic alkalizing reagent in exhaust steam as an auxiliary.
机译:直接风冷的冷凝器(ACC)中的操作腐蚀在中国普遍存在。各种水处理装置用于冷凝水,以根据准则控制低于极限的给水铁浓度,但是直接ACC操作腐蚀仍然存在并需要彻底的溶液。氨在初始冷凝物中具有较低的分区系数,因为酸性阴离子浓缩在初始冷凝物中,因此初始冷凝物具有较低的pH值,这导致上述腐蚀。为了减少直接的ACC操作腐蚀,可以应用方法,例如在饲料水中给药的氨水量或将一些有机碱化试剂加入废气中作为辅助剂。