A new measurement method of the multiple-circuit transmission lines' power frequency impedance parameters on the same.tower is proposed in this paper based on the assumption of the threephase unbalance and induced voltage is constant in a short time. By applying a single-phase AC supply and multiple measurements, the mathematical model of the double-circuit transmission lines' power frequency impedance parameters based on the measured voltage and current is established, and then the sequence impedances and sequence coupled impedances can be resolved. This method is simple, accurate and without the influence of three-phase unbalance on the measurement of transmission line parameters. The simulation results show the validity of the proposed method.
机译:一种新的多电路传输线的功率频率阻抗参数的新测量方法。在本文中提出了基于三相不平衡的假设,并且在短时间内恒定的诱导电压恒定地提出了电力。通过应用单相AC供应和多次测量,建立了基于测量电压和电流的双电路传输线的功率频率阻抗参数的数学模型,然后可以解决序列阻抗和序列耦合阻抗。该方法简单,准确,而不会对传输线参数测量的三相不平衡的影响。仿真结果表明了该方法的有效性。