首页> 外文会议> >A high TCR material with Si1#x2212;xGex/Si MQWs for waterborne pathogen detection
【24h】

A high TCR material with Si1#x2212;xGex/Si MQWs for waterborne pathogen detection

机译:具有Si1-xGex / Si MQW的高TCR材料用于水性病原体检测

获取原文
获取原文并翻译 | 示例

摘要

The thermistor based on Si1−xGex/Si MQWs structure is one kind of biomedical materials which used in waterborne pathogen detection. Si1−xGex/Si MQWs structure has high temperature coefficient of resistance (TCR), which meets the requirements for the detection of exothermic phenomenon during the reaction. In this work the theoretical model of the material has been introduced. The energy gap in valence band between barrier valence band level and Fermi level is 0.16ev and 0.21ev in the experiment and theoretical analysis respectively. The TCR values with different structure of the MQWs (25% and 30% Ge content with 10 nm wide quantum well) are −2.84% and −3.25% in the calculation respectively. The TCR test experiment has been carried out and a TCR value of −2.3 %/K was obtained after data processing.
机译:基于Si 1-x Ge x / Si MQWs结构的热敏电阻是一种用于水生病原体检测的生物医学材料。 Si 1-x Ge x / Si MQWs结构具有较高的电阻温度系数(TCR),满足检测反应过程中放热现象的要求。在这项工作中,已经介绍了材料的理论模型。在实验和理论分析中,势垒价带能级和费米能级之间的价带能隙分别为0.16ev和0.21ev。在计算中,具有不同结构的MQW的TCR值(Ge含量为25%和30%,量子阱为10 nm)分别为-2.84%和-3.25%。进行了TCR测试实验,数据处理后的TCR值为-2.3%/ K。