首页> 中文期刊> 《低温与超导》 >竖直圆管内液氮流动沸腾流动压降的分析

竖直圆管内液氮流动沸腾流动压降的分析

         

摘要

This paper presented an experimental investigation on the pressure drop during flow boiling of liquid nitrogen in a vertical tube. The affect of heat flux and mass flow rate on the friction pressure drop during two - phase flow of liquid nitrogen was analyzed. Results showed that the two—phase flow pressure drop increased with the increasing of heat flux and mass flow rale. The total pressure drop during the test section decreased with the increasing of heat flux. The calculated results with homogeneous model, the L-M model and Chisholm B coefficient model showed that the homogeneous model could give good prediction.%文中对竖直圆管内液氮流动沸腾压降进行实验研究,分析热流密度、质量流量对液氮两相流动摩擦压降的影响以及热流密度对测试段总压降的影响.在本实验工况范围内,两相流摩擦压降随着热流密度和质量流速的增加而变大,且测试段总压降随着热流密度的增加而降低.分别利用均相模型、L-M模型和Chisholm B系数模型对实验结果进行预测,并比较了预测值与实验值,结果表明本实验工况下均相模型预测效果最好.

著录项

  • 来源
    《低温与超导》 |2012年第8期|23-27|共5页
  • 作者单位

    上海交通大学制冷与低温工程研究所,上海200240;

    上海交通大学制冷与低温工程研究所,上海200240;

    上海交通大学制冷与低温工程研究所,上海200240;

    南海舰队湛江装备机动修理队,湛江524000;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    流动沸腾; 液氮; 两相流; 压降;