首页> 外文期刊>Chemosphere >Evaluation of the QuEChERS method for the extraction of Pharmaceuticals and personal care products from drinking-water treatment sludge with determination by UPLC-ESI-MS/MS
【24h】

Evaluation of the QuEChERS method for the extraction of Pharmaceuticals and personal care products from drinking-water treatment sludge with determination by UPLC-ESI-MS/MS

机译:用UPLC-ESI-MS / MS测定从饮用水处理污泥中提取药物和个人护理产品的QuEChERS方法的评估

获取原文
获取原文并翻译 | 示例
           

摘要

A modified version of the QuEChERS method has been evaluated for the determination of 21 pharmaceuticals and 6 personal care products (PPCPs) in drinking-water sludge samples by employing ultra high liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The performance of the method was evaluated through linearity, recovery, precision (intra-day), method detection and quantification limits (MDL and MQL) and matrix effect. The calibration curves prepared in acetonitrile and in the matrix extract showed a correlation coefficient ranging from 0.98 to 0.99. MQLs values were on the ng g~(-1) order of magnitude for most compounds. Recoveries between 50% and 93% were reached with RSDs lower than 10% for most compounds. Matrix effect was almost absent with values lower than 16% for 93% of the compounds. By coupling a quick and simple extraction called QuEChERS with the UPLC-MS/MS analysis, a method that is both selective and sensitive was obtained. This methodology was successfully applied to real samples and caffeine and benzophenone-3 were detected in ng g~(-1) levels.
机译:QuEChERS方法的改进版本已通过超高液相色谱-串联质谱法(UPLC-MS / MS)进行了评估,用于测定饮用水污泥样品中的21种药品和6种个人护理产品(PPCP)。通过线性,回收率,精密度(日内),方法检测和定量极限(MDL和MQL)以及基质效应评估了该方法的性能。在乙腈和基质萃取物中制备的校准曲线显示相关系数在0.98至0.99之间。大多数化合物的MQLs值在ng g〜(-1)数量级。大多数化合物的回收率均低于10%,回收率达到50%至93%。对于93%的化合物,几乎没有基质效应,其值低于16%。通过将称为QuEChERS的快速,简单提取与UPLC-MS / MS分析结合起来,获得了一种既选择性又灵敏的方法。该方法已成功应用于实际样品中,并以ng g〜(-1)的水平检测到了咖啡因和二苯甲酮3。

著录项

  • 来源
    《Chemosphere》 |2014年第7期|74-82|共9页
  • 作者单位

    Post-Graduation Program in Technological and Environmental Chemistry, Escola de Quimica e Alimentos, Laboratorio de Analise de Compostos Organicos e Metais (LACOM), Universidade Federal do Rio Grande, Av Italia, km 8, s, Rio Grande, Rio Grande do Sul State 96201-900, Brazil;

    Post-Graduation Program in Technological and Environmental Chemistry, Escola de Quimica e Alimentos, Laboratorio de Analise de Compostos Organicos e Metais (LACOM), Universidade Federal do Rio Grande, Av Italia, km 8, s, Rio Grande, Rio Grande do Sul State 96201-900, Brazil;

    Post-Graduation Program in Technological and Environmental Chemistry, Escola de Quimica e Alimentos, Laboratorio de Analise de Compostos Organicos e Metais (LACOM), Universidade Federal do Rio Grande, Av Italia, km 8, s, Rio Grande, Rio Grande do Sul State 96201-900, Brazil;

    Laboratorio de Analises de Residuos de Pesticidas (LARP), Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil;

    Laboratorio de Analises de Residuos de Pesticidas (LARP), Universidade Federal de Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil;

    Post-Graduation Program in Technological and Environmental Chemistry, Escola de Quimica e Alimentos, Laboratorio de Analise de Compostos Organicos e Metais (LACOM), Universidade Federal do Rio Grande, Av Italia, km 8, s, Rio Grande, Rio Grande do Sul State 96201-900, Brazil;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    UPLC-MS/MS; Drinking-water sludge samples; PPCPs; QuEChERS;

    机译:UPLC-MS / MS;饮用水污泥样品;PPCP;QuEChERS;