首页> 外文期刊>Chromatographia >Preparation of Titania Monolith Column and Application in Determination of Benzoic Acid by HILIC
【24h】

Preparation of Titania Monolith Column and Application in Determination of Benzoic Acid by HILIC

机译:钛白粉整体柱的制备及其在HILIC测定苯甲酸中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

The titania monolith column has been synthesized through a template-free sol–gel route, and a simple and reliable method for the determination of benzoic acid by hydrophilic interaction liquid chromatography using the prepared titania monolith has been developed. The influences of acetonitrile, acetate buffer and buffer pH on the retention of benzoic acid were investigated. Benzoic acid in carbonated drinks and fruit beverages samples were determined within 5 min and quantitative analysis was carried out by external standard method with a correlation coefficient (R 2) of 0.9984. The relative standard deviation was 0.91 % and the recovery ranged from 92.5 to 101.3 %. The proposed method is suitable for the analysis of benzoic acid in beverage samples.
机译:二氧化钛整体柱是通过无模板的溶胶-凝胶路线合成的,并且已经开发了一种简单可靠的方法,可以使用制备的二氧化钛整体柱通过亲水相互作用液相色谱法测定苯甲酸。研究了乙腈,乙酸盐缓冲液和缓冲液pH对苯甲酸保留的影响。在5分钟内测定碳酸饮料和水果饮料样品中的苯甲酸,并采用外标法进行定量分析,相关系数(R 2 )为0.9984。相对标准偏差为0.91%,回收率范围为92.5至101.3%。该方法适用于饮料样品中苯甲酸的分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号