摘要

An experimental investigation of the thermal performance of a flat plate heat pipe is presented in this work. The results indicate that the temperature along the heat pipe wall surfaces is quite uniform. The results also indicate that the porous wick of the evaporator section creates the main thermal resistance resulting in the largest temperature drop, which consequently affects the performance of the heat pipe. The idea of the heat pipe time constant is introduced in this work to describe the transient characteristics of the flat plate heat pipe and an empirical correlation for the time constant in terms of input heat flux is presented. Correlations for the maximum temperature rise and maximum temperature difference within the heat pipe are also presented. The experimental results at steady state were compared with the analytical results and found to be in good agreement. This work constitutes the first detailed experimental investigation of a fiat plate heat pipe.
机译:这项工作提出了对平板热管的热性能的实验研究。结果表明,沿热管壁表面的温度相当均匀。结果还表明,蒸发器部分的多孔芯会产生主要的热阻,从而导致最大的温度下降,从而影响热管的性能。本文介绍了热管时间常数的概念,以描述平板热管的瞬态特性,并给出了时间常数与输入热通量之间的经验相关性。还介绍了热管内最大温升和最大温差的关系。将稳态下的实验结果与分析结果进行比较,发现结果吻合良好。这项工作是对平板式热管进行的首次详细实验研究。