To summarize the process, we need to make four noise power measurements read on the spectrum analyzer: 1. A calibrated noise source connected directly to the test measurement circuit input. This would be connected to the buffer amplifier shown in Figure 2. Call this P1. 2. A second calibrated noise source (or the first source with a high precision, measured attenuator at its output) connected to the buffer amplifier shown in Figure 2. Call this P2. 3. The DUT with its input terminated in a matched load (290K) connected to the test circuit. Call this P3. 4. The DUT with its input terminated with a calibrated noise source connected to the test circuit. Call this P4.
机译:为了总结该过程,我们需要在频谱分析仪上读取四个噪声功率测量:1。直接连接到测试测量电路输入的校准噪声源。这将连接到图2所示的缓冲放大器。调用该P1。 2.第二校准的噪声源(或具有高精度的第一源,其输出高精度,测量衰减器)连接到图2中所示的缓冲放大器。调用该P2。 3. DUT,其输入终止于连接到测试电路的匹配负载(290K)。打电话给这个p3。 4. DUT与其输入终止,校准噪声源连接到测试电路。打电话给这个p4。