首页> 外文期刊>日本建築学会構造系論文集 >機械的固定工法による防水システムの耐風性に関する研究: 加圧実験と風洞実験による防水システムの性状変化について
【24h】

機械的固定工法による防水システムの耐風性に関する研究: 加圧実験と風洞実験による防水システムの性状変化について

机译:通过机械固定方法研究防水系统的抗风性:通过加压试验和风洞试验来改变防水系统的性能

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The pressure test and the wind tunnel test were carried out to obtain basic data for wind resistance design method of a mechanically anchored waterproofing membrane system. The test specimen was a flat roof with dimensions; 2.4nrwide, 3m-length and 0.29m-height. The waterproofing material was polyester fiber-reinforced PVC sheet. In pressure test, because the applied pressure is equivalent pressure on all area of the roof, the billowing height of PVC sheet around fastener were almost same values. Therefore, the vertical force at fastener was also same with the pressure induced by a compressor and horizontal force was approximately ON. On the other hand, the strain of PVC sheet around fastener at windward was larger than that of leeward in the wind tunnel test. Then, the horizontal force was 70% of vertical force at mean wind speed of 38.6 m/s. Therefore, it was clear that characteristic of mechanically anchored waterproofing membrane system in pressure test and wind tunnel test was different.%機械的固定工法による防水システムの耐風設計用資料を得るため、rn実大試験体による下面からの加圧試験および風洞実験を実施した。得rnられた結論は以下の通りである。rn1)風洞を用いた強風下での防水層機械的固定部の鉛直力と水平力rnの同時測定を行い、固定部にはその前後の風圧力の差に起因するrn強い水平力が生じていることを見出した。
机译:进行了压力测试和风洞测试,以获得机械锚固防水膜系统的抗风设计方法的基础数据。测试样品是具有一定尺寸的平屋顶。宽2.4nr,长3m,高0.29m。防水材料是聚酯纤维增强的PVC片。在压力测试中,由于所施加的压力等于在屋顶的所有区域上的等效压力,因此紧固件周围的PVC板的滚滚高度几乎是相同的值。因此,紧固件上的垂直力也与压缩机产生的压力相同,水平力大约为ON。另一方面,在风洞试验中,PVC板在迎风处周围的应变大于背风。然后,在平均风速为38.6 m / s时,水平力为垂直力的70%。因此,很明显,在压力测试和风洞测试中,机械锚固防水膜系统的特性是不同的。%机械的固定工法による防水システムの耐风设计用资料を得るため,rn実大试験体による下面からの加rn1)风洞を用いた强风下での防水层机械的固定部の铅直力と水平力rnの同时测定を行い,固定部にはその前后の风圧力の差に起因するrn强い水平力が生じていることを见出した。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号