Planar screen-printed platinum electrodes developed for use in corrosion monitoring have been evaluated using cyclic differential pulse voltammetry and shown to detect cupric ions (Cu2+) over a range up to 100 mM in a background of 3.5% by weight sodium chloride solution. The reduction of Cu2+ to metallic copper is shown to proceed as two successive single-electron transfer reactions involving an intermediate chemical step where the cuprous ion (Cu+) is complexed by chloride to form the dichlorocuprous anion CuCl2-. By comparison, the complexation step during the oxidation of copper to Cu2+ can involve a number of different chlorocopper(I) complexes of the general form [CuCl(n+1)]n- depending on the chloride concentration, which can make detection via a stripping reaction difficult.
机译:已开发出用于腐蚀监测的平面丝网印刷铂电极,已使用循环差分脉冲伏安法进行了评估,结果显示可在3.5的背景下检测高达100 mM范围内的铜离子(Cu 2 + )重量百分比氯化钠溶液。 Cu 2 + 还原为金属铜的过程显示为两个连续的单电子转移反应,涉及一个中间化学步骤,其中亚铜离子(Cu + )被络合用氯化物形成二氯亚铜阴离子CuCl 2 -。相比之下,在将铜氧化为Cu 2 + 的过程中,络合步骤可能涉及许多不同形式的[CuCl (n + 1)] n-取决于氯化物的浓度,这会使通过汽提反应进行检测变得困难。